Mikrotik Power Supply Status
The Power Supply (Mikrotik) Check monitors the power supply on the specified Mikrotik device.
Basic Check information
Supported Systems/Applications |
SNMP-enabled devices that support the MIKROTIK-MIB |
Device Class |
Router |
Troubleshooting
Failed |
Ensure the correct SNMP community string is configured in Network Discovery for the device |
201 Exception
OID_TYPE_NOSUCHOBJECT |
Missing OID object on the device for specific metric |
SNMP Properties Queried
mtxrHlPowerSupplyState |
1.3.6.1.4.1.14988.1.1.3.15 |
mtxrHlBackupPowerSupplyState |
1.3.6.1.4.1.14988.1.1.3.16 |
mtxrHlVoltage |
1.3.6.1.4.1.14988.1.1.3.8 |
mtxrHlPower |
1.3.6.1.4.1.14988.1.1.3.12 |
mtxrHlCurrent |
1.3.6.1.4.1.14988.1.1.3.13 |
Calculations Performed
Power Supply State |
Power supply state from mtxrHlPowerSupplyState
- Pass: 1
- Fail: Less than 0 or Greater than or equal to 2
|
Backup Power Supply State |
Backup power supply from mtxrHlBackupPowerSupplyState
- Pass: 1
- Fail: Less than 0 or Greater than or equal to 2
|
Voltage |
Voltage from mtxrHlVoltage
- Pass = Between 240 and 250
- Fail = Less than 240 or Greater than 250
|
Wattage |
Wattage from mtxrHlPower
- Pass = Between 230 and 240>
- Fail = Less than 230 or Greater than 240
|
Current (Amps) |
Current from mtxrHlCurrent
- Pass = Between 960 and 970
- Fail = Less than 960 or Greater than 970
|