Volume (NetApp) Check
The Volume (NetApp) Check monitors the status and size of a logical volume on a NetApp SAN.
For more information, see www.netapp.com/us/.
Basic Check information
Check Type | SNMP |
---|---|
Discovery OID | 1.3.6.1.4.1.789.1.5.4.1.2 (Volume Name) |
Supported Systems/Application | NetApp device with SNMP enabled. |
Max. Instances Per Device | 1 |
Supported Device Class | Storage |
Troubleshooting
Issue | Corrective Action |
---|---|
Failed | Please check that the correct SNMP community string is configured in Network Discovery for the device |
201 Exception OID_TYPE_NOSUCHOBJECT | Missing OID object on the device for specific metric |
Metrics 1
OID | 1.3.6.1.4.1.789.1.5.4.1.29 |
---|
Calculations Performed
OID Used for this Metric | Supported Values | Calculations/ Threshold Mapping |
Default Thresholds |
---|---|---|---|
Volume Size | N/A | N/A | Off |
Metrics 2
OID | 1.3.6.1.4.1.789.1.5.4.1.30 |
Calculations Performed
OID Used for this Metric | Supported Values | Calculations/ Threshold Mapping |
Default Thresholds |
---|---|---|---|
Free Space | N/A | Volume Size – Used Space * 1024 |
Off |
Disk Utilization | N/A | Volume Size – Used Space * 100 |
Normal: 0-85 Warning: 80-95 Failed: 90-100 |