Temperature Status (Cisco) Check
The Temperature Status (Cisco) Check monitors the temperature of the specified Cisco device.
Basic Check information
Check Type | SNMP |
---|---|
Instances on a Device | 1 |
Supported Systems/Applications | Most Cisco switches/routers running IOS. |
Device Class | Switch/Router |
Temperature Sensor | The name of the monitored temperature sensor. |
Troubleshooting
Issue | Corrective Action |
---|---|
Failed | Please check that the correct SNMP community string is configured in Network Discovery for the device |
201 Exception OID_TYPE_NOSUCHOBJECT | Missing OID object on the device for specific metric |
SNMP Properties Queried
Object Descriptors | Numerical OID |
---|---|
$Temperature | 1.3.6.1.4.1.9.9.13.1.3.1.3 |
$TempSensorStatus | 1.3.6.1.4.1.9.9.13.1.3.1.6 |
$HighTemp | 1.3.6.1.4.1.9.9.13.1.3.1.4 |
Calculations Performed
Status Detail | Description |
---|---|
Temperature (°C) | The current temperature reading. |
Maximum Allowable Temperature (°C) | The maximum allowable operating temperature of the device. |
Temperature (°F) | The current temperature reading. |
Maximum Allowable Temperature (°F) | The maximum allowable operating temperature of the device. |
Temperature Sensor Status |
The temperature sensor status is mapped as follows:
|
Temperature Sensor Status Description |
Describes the status of the temperature sensor:
|