Temperature Status (Cisco) Check
The Temperature Status (Cisco) Check monitors the temperature of the specified Cisco device.
Basic Check information
| Check Type | SNMP |
|---|---|
| Instances on a Device | 1 |
| Supported Systems/Applications | Most Cisco switches/routers running IOS. |
| Device Class | Switch/Router |
| Temperature Sensor | The name of the monitored temperature sensor. |
Troubleshooting
| Issue | Corrective Action |
|---|---|
| Failed | Please check that the correct SNMP community string is configured in Network Discovery for the device |
| 201 Exception OID_TYPE_NOSUCHOBJECT | Missing OID object on the device for specific metric |
SNMP Properties Queried
| Object Descriptors | Numerical OID |
|---|---|
| $Temperature | 1.3.6.1.4.1.9.9.13.1.3.1.3 |
| $TempSensorStatus | 1.3.6.1.4.1.9.9.13.1.3.1.6 |
| $HighTemp | 1.3.6.1.4.1.9.9.13.1.3.1.4 |
Calculations Performed
| Status Detail | Description |
|---|---|
| Temperature (°C) | The current temperature reading. |
| Maximum Allowable Temperature (°C) | The maximum allowable operating temperature of the device. |
| Temperature (°F) | The current temperature reading. |
| Maximum Allowable Temperature (°F) | The maximum allowable operating temperature of the device. |
| Temperature Sensor Status |
The temperature sensor status is mapped as follows:
|
| Temperature Sensor Status Description |
Describes the status of the temperature sensor:
|