Spare Drive (NetApp) Check

Spare Drive (NetApp) Check monitors the status of a spare drive in a RAID array on a NetApp SAN.

Basic Check information

Check Type SNMP
Discovery OID 1.3.6.1.4.1.789.1.6.3.1.2 (spareDiskName)
Supported Systems/Application NetApp Device with SNMP enabled.
Max. Instances Per Device 100
Supported Device Class Storage

Troubleshooting

Issue Corrective Action
Failed Please check that the correct SNMP community string is configured in Network Discovery for the device
201 Exception OID_TYPE_NOSUCHOBJECT Missing OID object on the device for specific metric

Metrics

OID:  1.3.6.1.4.1.789.1.6.3.1.3 Default Thresholds Notes
Status

1- 1 Normal

2- 2-4 Warning

3- 6-10 Failed

 
Status Description off {spare(1), addingspare(2), bypassed(3), unknown(4), offline(10)}

 

OID: 1.3.6.1.4.1.789.1.6.3.1.16 Default Thresholds Notes
Serial Number off Serial number of the referenced disk drive.

 

OID: 1.3.6.1.4.1.789.1.6.3.1.17 Default Thresholds Notes
Vendor off Vendor of the referenced disk drive.

 

OID: 1.3.6.1.4.1.789.1.6.3.1.18 Default Thresholds Notes
Model off Model string of the referenced disk drive.

 

OID: 1.3.6.1.4.1.789.1.6.3.1.19 Default Thresholds Notes
Firmware Version off Firmware revision number of the referenced disk drive.

 

OID: 1.3.6.1.4.1.789.1.6.3.1.20 Default Thresholds Notes
Disk Speed (R.P.M.) off  

 

OID: 1.3.6.1.4.1.789.1.6.3.1.21 Default Thresholds Notes
Disk Type off Interface type of the referenced disk drive (for example, SCSI).