Power Supply (EqualLogic) Check

The Power Supply (EqualLogic) Check monitors the overall condition of the power supply for a Dell EqualLogic SAN.

Basic Check information

Check Type SNMP
Instances on a Device 5
Supported Systems/Applications Dell EqualLogic SANs that support the EQLMEMBER-MIB MIB
Device Class Server - Generic and Server - Windows

Troubleshooting

Issue Corrective Action
Failed Please check that the correct SNMP community string is configured in Network Discovery for the device
201 Exception OID_TYPE_NOSUCHOBJECT Missing OID object on the device for specific metric

OID/Calculation

Metric Name OID/Calculation Description
Power Supply Status 1.3.6.1.4.1.12740.2.1.8.1.3

The status of the power supply mapped as:

  • 1: On and operating
  • 2: No AC power
  • 3: Failed or no data
Power Supply Fan Status 1.3.6.1.4.1.12740.2.1.8.1.4

If the Power Supply Status is on and operating, this field indicates that the operational state of the fan.

Fan states are mapped as:

  • 0: Not applicable
  • 1: Fan is operational
  • 2: Fan is not operational
Power Supply Firmware Version 1.3.6.1.4.1.12740.2.1.8.1.5 Specifies the firmware version of the power supply.