Dell PowerConnect Power Supply Check
The Dell PowerConnect Power Supply Check uses SNMP to monitor power supply state, power source and current power consumption on a Dell PowerConnect switch.
Basic Check information
| Supported Systems/Application |
SNMP-enabled devices that support the Dell PowerConnect MIB |
| Supported Device Class |
Switch |
Troubleshooting
| Failed |
Please check that the correct SNMP community string is configured in Network Discovery for the device |
| 201 Exception
OID_TYPE_NOSUCHOBJECT |
Missing OID object on the device for specific metric |
Metrics
| Description |
No thresholds |
| Power Supply State |
Normal: 1 Failed: 2-255 |
| Power Supply State Description |
No thresholds |
| Power Source |
No thresholds |
| Current Power Consumption |
No thresholds |
SNMP Properties Queried
| descr |
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.2 |
| state |
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.3 |
| powerSource |
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.4 |
| currentPowerConsumption |
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5 |
Calculations Performed
| Description |
descr |
| Power Supply State |
state |
| Power Supply State Description |
state - mapped to: 1 - Normal 2 - Warning 3 - Critical 4 - Shutdown 5 - Not Present 6 - Not Functioning
|
| Power Source |
powerSource – mapped to:1 - Unknown 2 - AC 3 - DC 4 - External Power Supply 5 - Internal Redundant
|
| Current Power Consumption |
currentPowerConsumption |