Power Supply (Cisco) Check
The Power Supply (Cisco) Check monitors the state of the specified power supply, and it's line input, on a Cisco device.
Basic Check information
| Instances on a Device |
1 |
| Supported Systems/Applications |
Most Cisco switches/routers running IOS. |
| Device Class |
Switch/Router |
Troubleshooting
| Failed |
Please check that the correct SNMP community string is configured in Network Discovery for the device |
| 201 Exception
OID_TYPE_NOSUCHOBJECT |
Missing OID object on the device for specific metric |
SNMP Properties Queried
| $PSState |
1.3.6.1.4.1.9.9.13.1.5.1.3 |
| $PSSource |
1.3.6.1.4.1.9.9.13.1.5.1.4 |
Calculations Performed
| Power Supply State |
The status of the power supply which is mapped as:- Normal: 1
- Warning: 2
- Failed: 3-6
|
| Power Supply State Description |
A description of the power supply's state as:- 1: Normal
- 2: Warning
- 3: Critical
- 4: Shutdown
- 5: Not Present
- 6: Not Functioning
|
| Power Supply Source |
The line input of the power supply. |