Physical Drive (NetApp) Check

Physical Drive (NetApp) Check Monitors the status of a physical drive in a RAID array on a NetApp SAN.

For more information, see www.netapp.com/us/.

Basic Check information

Check Type SNMP
Discovery OID 1.3.6.1.4.1.789.1.6.2.1.2 (Volume Name)
Supported Systems/Application NetApp device with SNMP enabled
Max. Instances Per Device 100

Supported Device Class

Storage

Troubleshooting

Issue Corrective Action
Failed Please check that the correct SNMP community string is configured in Network Discovery for the device
201 Exception OID_TYPE_NOSUCHOBJECT Missing OID object on the device for specific metric

Metrics 1

OID
1.3.6.1.4.1.789.1.6.2.1.3

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Status N/A N/A 1: Normal
2-5: Warning
6-10: Failed
Status Description N/A N/A Off

Metrics 2

OID 1.3.6.1.4.1.789.1.6.2.1.27

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Serial Number N/A N/A Off

Metrics 3

OID 1.3.6.1.4.1.789.1.6.2.1.28

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Model N/A N/A Off

Metrics 4

OID 1.3.6.1.4.1.789.1.6.2.1.29

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Firmware Version N/A N/A Off

Metrics 5

OID 1.3.6.1.4.1.789.1.6.2.1.30

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Disk Speed N/A N/A Off

Metrics 6

OID 1.3.6.1.4.1.789.1.6.2.1.31

 

OID Used for this Metric Supported Values Calculations/
Threshold Mapping
Default Thresholds
Disk Type N/A N/A Off

We are not responsible for the content of external sites.