Dell PowerConnect Fan Check
The Dell PowerConnect Fan Check uses SNMP to monitor both the state and speed of fans on a Dell PowerConnect switch.
Basic Check information
Check Type | SNMP |
---|---|
Supported Systems/Application | SNMP-enabled devices that support the Dell PowerConnect MIB |
Supported Device Class | Switch |
Troubleshooting
Issue | Corrective Action |
---|---|
Failed | Please check that the correct SNMP community string is configured in Network Discovery for the device |
201 Exception OID_TYPE_NOSUCHOBJECT | Missing OID object on the device for specific metric |
Metrics
Name | Default Thresholds |
---|---|
Description |
No thresholds |
Fan State |
Normal: 0,1 Failed: 2-255 |
Fan State Description | No thresholds |
Fan Speed | No thresholds |
SNMP Properties Queried
Variable Name | SNMP OID |
descr | 1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.2 |
fs | 1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.3 |
sp | 1.3.6.1.4.1.674.10895.3000.1.2.110.7.1.1.4 |
Calculations Performed
Variable Name | Calculation |
Description | descr |
Fan State | fs |
Fan State Description |
fs - mapped to:
|
Fan Speed | sp |