Fan Status (NetApp) Check
The Fan Status (NetApp) Check monitors Indicates how many fans have failed.
For more information, see www.netapp.com/us/.
Basic Check information
Check Type | SNMP |
---|---|
Discovery OID | Index 0 |
Supported Systems/Application | NetApp device with SNMP enabled. |
Troubleshooting
Issue | Corrective Action |
---|---|
Failed | Please check that the correct SNMP community string is configured in Network Discovery for the device. For more information, see Place Network under Management. |
201 Exception OID_TYPE_NOSUCHOBJECT | Missing OID object on the device for specific metric |
Information
Max. Instances Per Device | 1 |
Supported Device Class | Storage |
Notification Profile | N/A |
Metrics 1
OID | 1.3.6.1.4.1.789.1.2.4.2 |
OID Used for this Metric | Supported Values | Calculations/ Threshold Mapping |
Default Thresholds |
---|---|---|---|
Failed Chassis Fans | N/A | N/A | 1 – {0}Normal
2 – {>1} Failed |
Metrics 2
OID | 1.3.6.1.4.1.789.1.2.4.3 |
OID Used for this Metric | Supported Values | Calculations/ Threshold Mapping |
Default Thresholds |
---|---|---|---|
Chassis Fans Status | N/A | N/A | Off |
We are not responsible for the content of external sites.