ADTRAN - Device Health Check

The ADTRAN - Device Health Check monitors the health of ADTRAN switch/router devices.

Basic Check information

Check Type SNMP
Instances on a Device 1
Supported Systems/Applications ADTRAN Switch/Router devices that support the ADTRAN-AOSCPU MIB
Device Class Switch/Router

Troubleshooting

Issue Corrective Action
Failed Please check that the correct SNMP community string is configured in Network Discovery for the device
201 Exception OID_TYPE_NOSUCHOBJECT Missing OID object on the device for specific metric

OID/Calculation

Metric Name OID/Calculation Description
Device Health Summary 1.3.6.1.4.1.664.5.53.1.1.7

Device Health is mapped as:

  • Okay: 0 to 3
  • Warning: 4
  • Failed: 5, 6
Device Health State  

Returns the following states:

  • (1) Unknown
  • (2) Unused
  • (3) OK
  • (4) Warning
  • (5) Critical
  • (6) Non-recoverable