RAID Status (Dell) service

The RAID Status (Dell) service monitors the state of the RAID controller only.

To monitor the firmware version, use RAID Controller Firmware (Dell). To monitor the battery status of the RAID controller, use RAID Battery Status (Dell).

Basic service information

Manufacturer/Public Information
Service TypeSNMP
Discovery OID1.3.6.1.4.1.674.10893.1.20.130.1.1.2 (ControllerName)
Supported Systems/ApplicationsRAID configured Dell with SNMP enabled.
N-able - N-central Specific Information
Known limitations N/A
Max Instances on each device 100
Supported Device class Windows / Linux
Notification Profile N/A
Monitored byWindows agent, Windows probe

Troubleshooting

IssueCorrective Action
misconfiguredVerify that you have the correct SNMP credentials.

Metrics

OID usedSupported ValuesCalculations/Threshold Mapping Default ThresholdsNotes

1.3.6.1.4.1.674.10893.1.20.130.1.1.5

Status

The status of the controller is mapped as:

  • Normal: 1, 3
  • Warning: 0, 6
  • Failed: 2, 4

The current condition of the controller subsystem, including devices connected to it.

  • 0:Unknown
  • 1:Ready
  • 2:Failed
  • 3:Online
  • 4:Offline
  • 6:Degraded

1.3.6.1.4.1.674.10893.1.20.130.1.1.5

Controller Type

Off

The type of controller:

  • 1:SCSI
  • 2:PV660F
  • 3:PV662F
  • 4:IDE (Integrated/Intelligent Drive Electronics)
  • 5:SATA (Serial Advanced Technology Attachment)
  • 6:SAS (Serial Attached SCSI)

1.3.6.1.4.1.674.10893.1.20.130.1.1.5

Controller Name

OffThe name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example, Perc3/QC 1