RAID Battery Status (Dell) service
The RAID Battery Status (Dell) service monitors the state of batteries of the RAID controller. A Raid Controller can have more than one Battery.
Once an alert is received on this service, the user can run a Walk on .1.3.6.1.4.1.674.10893.1.20.130.16.1 to find the relationship between the Battery Index and corresponding Controller.
Basic service information
Manufacturer/Public Information | |
Service Type | SNMP |
Discovery OID | .1.3.6.1.4.1.674.10893.1.20.130.16.1.3 (BatteryConnectionNumber) |
Supported Systems/Applications | RAID configured Dell with SNMP enabled. |
N-able N-central Specific Information | |
Known limitations | N/A |
Max Instances on each device | 100 |
Supported Device class | Windows / Linux |
Notification Profile | N/A |
Monitored by | Windows and Linux agent, Windows probe |
Troubleshooting
Issue | Corrective Action |
---|---|
misconfigured | Ensure you have the correct SNMP credentials. |
Metrics
OID used | Supported Values | Calculations/Threshold Mapping | Default Thresholds | Notes |
---|---|---|---|---|
1.3.6.1.4.1.674.10893.1.20.130.15.1.4 | — | — | The status of the battery is mapped as:
| The meanings of the statuses:
|
1.3.6.1.4.1.674.10893.1.20.130.15.1.2 | — | — | Off | The battery's name as represented in Storage Management. |