Power Supply (Intel) Service
The Power Supply (Intel) service monitors the overall condition of the specified power supply on a server with an Intel Motherboard.
Special Note
This service operates in conjunction with the vendor-supplied hardware agent and requires SNMP to be configured so that it is accessible from both the N-able N-central Agent and the N-able N-central Probe.
The following are the requirements in order to associate this service with a device:
- The device must undergo discovery using a Probe-based asset scan.
- You need to enable SNMP enabled on the device on the Properties tab of the device.
- Once you enable SNMP for the device, you need to configure a community string. The default community string is public.
| Service Type | SNMP |
| Instances on a Device | 2 |
| Supported Systems/Applications | Devices using an Intel motherboard, with the Intel SMS software installed. |
| Device Class | Server - Generic, Server - Windows |
| Monitored By | Windows probes |
| Scan Interval | 5 minutes |
| Power Supply Name | The name of the monitored power supply. You can obtain the names of power supplies available for monitoring by querying the device with the 1.3.6.1.4.1.343.2.10.3.5.400.20.1.3 SNMP OID. |
OID/Calculation
| Metric Name | OID/Calculation | Description |
|---|---|---|
| Power Supply Status | 1.3.6.1.4.1.343.2.10.3.5.400.20.1.5 | The status of the power supply is mapped as...
... where ...
|
| Power Supply Status Description | 1.3.6.1.4.1.343.2.10.3.5.400.20.1.5 | Describes the status of the power supply as one of:
|
