Power Supply (Intel) Service
The Power Supply (Intel) service monitors the overall condition of the specified power supply on a server with an Intel Motherboard.
Special Note This service operates in conjunction with the vendor-supplied hardware agent and requires SNMP to be configured so that it is accessible from both the N-able N-central Agent and the N-able N-central Probe. The following are the requirements in order to associate this service with a device:
|
Service Type | SNMP |
Instances on a Device | 2 |
Supported Systems/Applications | Devices using an Intel motherboard, with the Intel SMS software installed. |
Device Class | Server - Generic, Server - Windows |
Monitored By | Windows probes |
Scan Interval | 5 minutes |
Power Supply Name | The name of the monitored power supply. You can obtain the names of power supplies available for monitoring by querying the device with the 1.3.6.1.4.1.343.2.10.3.5.400.20.1.3 SNMP OID. |
OID/Calculation
Metric Name | OID/Calculation | Description |
---|---|---|
Power Supply Status | 1.3.6.1.4.1.343.2.10.3.5.400.20.1.5 | The status of the power supply is mapped as...
... where ...
|
Power Supply Status Description | 1.3.6.1.4.1.343.2.10.3.5.400.20.1.5 | Describes the status of the power supply as one of:
|