The Logical Drive (Intel) service monitors the status of the logical drive attached to a supported Intel RAID controller.
Special Note
This service operates in conjunction with the vendor-supplied hardware agent and requires SNMP to be configured so that it is accessible from both the N-able N-central Agent and the N-able N-central Probe.
The following are the requirements in order to associate this service with a device:
- The device must undergo discovery using a Probe-based asset scan.
- You need to enable SNMP enabled on the device on the Properties tab of the device.
- Once you enable SNMP for the device, you need to configure a community string. The default community string is public.
| Service Type | SNMP |
| Instances on a Device | 1 |
| Monitored By | Windows probe |
| Scan Interval | 60 minutes |
| Drive Identifier | Type the SNMP identifier for the drive. You can find the identifier by querying the device with the 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.1 SNMP OID. |
OID/Calculation
| Metric Name | OID/Calculation | Description |
|---|---|---|
| Logical Drive State | 1.3.6.1.4.1.3582.4.1.4.3.1.2.1.5 | The current state of the monitored logical drive is mapped as...