Logical Drive (Adaptec) service
The Logical Drive (Adaptec) service monitors the status of the specified logical drive on an Adaptec RAID controller.
You need to install Adaptec Storage Manager or IBM ServeRAID Manager on the machine that you would like to monitor. For a complete list of supported models, see:
- http://www.adaptec.com/en-US/products/asm/
- https://www-304.ibm.com/systems/support/supportsite.wss/docdisplay?lndocid=MIGR-61707&brandind=5000008
Special Note This service operates in conjunction with the vendor-supplied hardware agent and requires SNMP to be configured so that it is accessible from both the N-able N-central Agent and the N-able N-central Probe. The following are the requirements in order to associate this service with a device:
|
Service Type | SNMP |
Instances on a Device | 10 |
Supported Systems/Applications | Any device using an Adaptec HostRAID card or an IBM ServeRAID card. |
Device Class | Server - Generic and Server - Windows |
Monitored By | Windows probes |
Scan Interval | 5 minutes |
Logical Drive | The name of the monitored logical drive. You can obtain the name by querying the device with the .1.3.6.1.4.1.795.14.1.1000.1.1.2 SNMP OID. |
OID/Calculation
Metric Name | OID/Calculation | Description |
---|---|---|
Logical Drive State | 1.3.6.1.4.1.795.14.1.1000.1.1.7 | Logical Drive State is mapped as:
The meanings for each of the possible drive states:
|
Logical Drive State Description | 1.3.6.1.4.1.795.14.1.1000.1.1.7 | The current health of the logical drive as:
|
RAID Level | 1.3.6.1.4.1.795.14.1.1000.1.1.4 | The RAID level used by this array. |
Task | 1.3.6.1.4.1.795.14.1.1000.1.1.6 | Task is mapped as:
The meanings for each of the possible mappings:
|
Task Description | 1.3.6.1.4.1.795.14.1.1000.1.1.6 | The task status of the logical drive as:
|
Task Completion | 1.3.6.1.4.1.795.14.1.1000.1.1.7 | Task is mapped as:
The meanings for each of the possible mappings:
|