RAID Controller Status (Fujitsu) service

The RAID Controller Status (Fujitsu) service monitors various elements of a RAID Controller in a Fujitsu device.

Service TypeSNMP
Instances on a Device100
Supported Systems/ApplicationsFujitsu servers running the Fujitsu ServerView agent.
Device Class for CPU (SNMP) Servers - Generic or Servers - Windows
Monitored ByWindows agent
RAID ContollerEnter the name of the monitored RAID controller. For a list of RAID controllers, query the device with the .1.3.6.1.4.1.231.2.49.1.4.2.1.25 SNMP OID.
ScanningYou can configure the scan interval according to either a Once a Day or Daily Interval schedule.

 

Object DescriptorsNumerical OID
$Manufacturer1.3.6.1.4.1.231.2.49.1.4.2.1.3
$Model1.3.6.1.4.1.231.2.49.1.4.2.1.2
$BusLocation1.3.6.1.4.1.231.2.49.1.4.2.1.5
$FirmwareRevision1.3.6.1.4.1.231.2.49.1.4.2.1.7
$BIOSRevision1.3.6.1.4.1.231.2.49.1.4.2.1.8
$NumberOfChannels1.3.6.1.4.1.231.2.49.1.4.2.1.9
$NumberOfPhysicalDisks1.3.6.1.4.1.231.2.49.1.4.2.1.11
$NumberOfLogicalDrives1.3.6.1.4.1.231.2.49.1.4.2.1.12
$CacheSize1.3.6.1.4.1.231.2.49.1.4.2.1.13
$Status1.3.6.1.4.1.231.2.49.1.4.2.1.15
$Interface1.3.6.1.4.1.231.2.49.1.4.2.1.16
$SerialNumber1.3.6.1.4.1.231.2.49.1.4.2.1.21
$DriverName1.3.6.1.4.1.231.2.49.1.4.2.1.22
$DriverRevision1.3.6.1.4.1.231.2.49.1.4.2.1.23
$BBUSStatus1.3.6.1.4.1.231.2.49.1.4.2.1.24
$UEFIDriverRevision1.3.6.1.4.1.231.2.49.1.4.2.1.27

 

Status DetailDescription
Controller Status

Describes the current status of the monitored RAID controller with values mapped as:

  1. NORMAL - OK
  2. WARNING - Warning
  3. FAILED - Error
  4. WARNING - Unknown
Battery Backup Status

Describes the current status of the backup battery for the monitored RAID controller with values mapped as:

  1. WARNING - Unknown
  2. NORMAL - Not Installed
  3. NORMAL - Normal
  4. WARNING - Charging
  5. WARNING - Discharging
  6. WARNING - Warning
  7. FAILED - Failed
ManufacturerThe name of the manufacturer of the RAID controller.
ModelThe model (descriptive name) of the RAID controller.
Serial NumberThe serial number of the RAID controller.
Firmware VersionThe version of the RAID controller firmware.
BIOS VersionThe version of the BIOS of the monitored RAID controller.
UEFI VersionThe version of the UEFI (Unified Extensible Firmware Interface) of the monitored RAID controller.
Driver NameThe name of the software driver for the monitored RAID controller.
Driver VersionThe version of the software driver for the monitored RAID controller.
Bus LocationThe location of the bus interface for the RAID controller that is being monitored.
Number of ChannelsThe number of hard disk channels available for the monitored RAID controller.
Number of Physical DisksThe total number of installed physical disks in the array.
Number of Logical DrivesThe total number of installed logical disks in the array.
Onboard Cache SizeThe size in megabytes, of the onboard cache within the array.
Disk Connection InterfaceThe type of disk interface of the monitored RAID controller, for example, IDE, SCSI, or SAS.