Temperature Status (EqualLogic) service
The Temperature Status (EqualLogic) service monitors the temperature of a Model PS6100 Dell EqualLogic SAN running v6.0.2 firmware.
| Service Type | SNMP |
| Instances on a Device | 1 |
| Supported Systems/Applications | Model PS6100 Dell EqualLogic SAN running v6.0.2 firmware. |
| Device Class | Server - Generic, Server - Windows |
| Monitored By | Windows agent |
| Scan Interval | 5 minutes |
| Temperature Sensor | Enter the name of the temperature sensor to monitor. For a list of temperature sensors, query the SAN with the .1.3.6.1.4.1.12740.2.1.6.1.2 SNMP OID. |
| Object Descriptors | Numerical OID |
|---|---|
| $Temperature | 1.3.6.1.4.1.12740.2.1.6.1.3 |
| $SensorState | 1.3.6.1.4.1.12740.2.1.6.1.4 |
| Status Detail | Description |
|---|---|
| Temperature (°C) | The current temperature reading. |
| Sensor State | The temperature sensor status is mapped as:
|
| Sensor State Description | Description of the status of the temperature sensor:
|