Power Supply (EqualLogic) Service
The Power Supply (EqualLogic) service monitors the overall condition of the power supply for a PS6100 Equallogic SAN using v6.0.2 firmware.
| Service Type | SNMP |
| Instances on a Device | 5 |
| Supported Systems/Applications | PS6100 Equallogic SANs using v6.0.2 firmware. |
| Device Class | Server - Generic and Server - Windows |
| Monitored By | Windows probe |
| Scan Interval | 5 minutes |
| Power Supply | Enter the name of the power supply to monitor. For a list of power supplies, query the SAN with the .1.3.6.1.4.1.12740.2.1.8.1.2 SNMP OID. |
OID/Calculation
| Metric Name | OID/Calculation | Description |
|---|---|---|
| Power Supply Status | 1.3.6.1.4.1.12740.2.1.8.1.3 | The status of the power supply mapped as:
|
| Power Supply Fan Status | 1.3.6.1.4.1.12740.2.1.8.1.4 | If the Power Supply Status is on and operating, this field indicates that the operational state of the fan. Fan states are mapped as:
|
| Power Supply Firmware Version | 1.3.6.1.4.1.12740.2.1.8.1.5 | Specifies the firmware version of the power supply. |