System Battery Status (Dell iDRAC) service

The System Battery Status (Dell iDRAC) service monitors the status of a system board CMOS battery on a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service TypeSNMP
Instances on a Device100
Supported Systems/ApplicationsDell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC).
Device Class for CPU (SNMP)Servers - Management Interface
Monitored ByWindows agent
Scan Interval15 minutes
SNMP ValueEnter or select the name of the battery to applied new templates. For a list of batteries, query the device with the .1.3.6.1.4.1.674.10892.5.4.600.50.1.7 SNMP OID.

 

Status DetailObject DescriptorsNumerical OIDDescription
Chassis Index$ChassisIndex1.3.6.1.4.1.674.10892.5.4.600.50.1.1The index of the system chassis that contains the battery as an integer value between 1 and 128.
Status$Status1.3.6.1.4.1.674.10892.5.4.600.50.1.5

The current status of the battery mapped as:

1 - other,
2 - unknown,
3 - ok,
4 - nonCritical,
5 - critical, and,
6 - nonRecoverable.