Network Card (Dell iDRAC) service

The Network Card (Dell iDRAC) service monitors the status of specified Network Interface Controllers (NICs) on a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).

Service TypeSNMP
Instances on a Device100
Supported Systems/ApplicationsDell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC).
Device Class for CPU (SNMP)Servers - Management Interface
Monitored ByWindows agent
Scan Interval15 minutes
SNMP ValueEnter or select the name of the network device to monitor in the format NetworkDevice FQDD (Fully Qualified Device Descriptor). For a list of network devices, query the device with the .1.3.6.1.4.1.674.10892.5.4.1100.90.1.30 SNMP OID.

Status DetailObject Descriptors Numerical OIDDescription
Product Name$Name1.3.6.1.4.1.674.10892.5.4.1100.90.1.6The product name of the network device.
MAC Address$MacAddress1.3.6.1.4.1.674.10892.5.4.1100.90.1.15The current MAC address of the network device.
Connection Status$ConnectionStatus1.3.6.1.4.1.674.10892.5.4.1100.90.1.4

The current connection status of the network device mapped as:

1 - connected
2 - disconnected
3 - driverBad
4 - driverDisabled
10 - hardwareInitalizing
11 - hardwareResetting
12 - hardwareClosing
13 - hardwareNotReady

Status$Status1.3.6.1.4.1.674.10892.5.4.1100.90.1.3

The current status of the network device mapped as:

1 - other,
2 - unknown,
3 - ok,
4 - nonCritical,
5 - critical, and,
6 - nonRecoverable.