Chassis Intrusion (Dell iDRAC) service
The Chassis Intrusion (Dell iDRAC) service monitors the chassis security feature that detects if a chassis component is removed or replaced from a Dell PowerEdge server using the embedded integrated Dell Remote Access Controller (iDRAC).
| Service Type | SNMP |
| Instances on a Device | 100 |
| Supported Systems/Applications | Dell PowerEdge servers with integrated Dell Remote Access Controller (iDRAC) |
| Device Class for CPU (SNMP) | Servers - Management Interface |
| Monitored By | Windows agent |
| Scan Interval | 15 minutes |
| SNMP Index | Enter or select the name of the SNMP index to be used by this service. |
| Status Detail | >Object Descriptors | Numerical OID | Description |
|---|---|---|---|
| Status | $Status | 1.3.6.1.4.1.674.10892.5.4.300.70.1.5 | The current status of the chassis intrusion sensor mapped as: 1 - other, |
| Reading | $Reading | 1.3.6.1.4.1.674.10892.5.4.300.70.1.6 | Indicates whether or not the chassis intrusion sensor is currently being read mapped as: 1 - chassisNotBreached, |
| Type | $Type | 1.3.6.1.4.1.674.10892.5.4.300.70.1.7 | Indicates the type of the intrusion sensor used for chassis security mapped as: 1 - chassisBreachDetectionWhenPowerON, and, |
| Settings | $Setting | 1.3.6.1.4.1.674.10892.5.4.300.70.1.4 | Indicates the current state settings of the intrusion sensor mapped as: 1 - unknown, |