Power Supply (Cisco) service

The Power Supply (Cisco) Service monitors the state of the specified power supply, and it's line input, on a Cisco device.

Service TypeSNMP
Instances on a Device1
Supported Systems/ApplicationsMost Cisco switches/routers running IOS.
Device ClassSwitch/Router
Monitored ByWindows probe
Scan Interval5 minutes
Power Supply IndexThe SNMP index of the power supply to be monitored. For a list of the fans installed in the Cisco device, query it with the 1.3.6.1.4.1.9.9.13.1.5.1.2 SNMP OID.
Power Supply NameThe name of the power supply to be monitored.

 

Object DescriptorsNumerical OID
$PSState1.3.6.1.4.1.9.9.13.1.5.1.3
$PSSource1.3.6.1.4.1.9.9.13.1.5.1.4

 

Status DetailDescription
Power Supply State

The status of the power supply which is mapped as:

  • Normal: 1
  • Warning: 2
  • Failed: 3-6
Power Supply State Description

A description of the power supply's state as:

  • 1: Normal
  • 2: Warning
  • 3: Critical
  • 4: Shutdown
  • 5: Not Present
  • 6: Not Functioning
Power Supply SourceThe line input of the power supply.