201 Automation Policy Timed Out error on Veeam Job Monitor or AMP-based services
Last Modified
Thu Jul 02 20:00 GMT 2020
Description
This article explains a common issue that occurs when multiple Veeam Job Monitor services or multiple AMP services are running on one device. This causes a "201 Automation policy timed out" error.
Environment
- N-able N-central9 or later
- AMP-based services
- Veeam Job Monitor
Solution
Veeam and AMP services typically have a default scheduled run time every 5 minutes. You may need to increase the scheduled run time to 20 minutes or more for each automation policy service. It may take a significant amount of time (up to 24 hours) to see if the services are providing the correct status.
- click the device name.
- click the service name (e.g. veeam job monitor)
- click the Service Details tab
- change the Scan Interval
- Save changes.
If this does not resolve your issue please contact support for further assistance.